Yesterday, 7 November, was the WebsiteInternational Day of Medical Physics 2026Visit the website , celebrated on Marie Skłodowska-Curie's birthday. It is a good opportunity to talk about what medical physicists do, including some work that patients rarely see.
Most patients never meet a medical physicist. But the quality of their scan or the accuracy of their external beam radiation therapy treatment depends on measurements, equipment, and procedures that a medical physicist has helped validate.
This year's theme, Advancing Global Health Equity: The Ethical Foundation of Medical Physics, also connects with a question I have been thinking about as theranostics programs expand. How do we build the expertise needed to deliver radiopharmaceutical therapies safely, and make that expertise available to more centres?
Medical physics comes in several flavors. We share a foundation but our clinical training and responsibilities differ. Those differences matter when we bring our expertise together in radiopharmaceutical therapy.
My view is that every theranostics program should have a named, board-certified nuclear medicine physicist accountable for its quantitative imaging and dosimetry workflow, working with colleagues across the treatment team. That certification should be supported by experience with the therapies and systems being used. I will explain why, and what I think that responsibility should involve.
One profession, several clinical specialties
Medical physicists share a foundation in physics and medical physics education: radiation physics, anatomy and physiology, radiobiology, instrumentation, imaging science, statistics, and radiation protection. The educational routes vary, and clinical training then develops depth in a particular specialty. The AAPM recognizes five subfields of medical physics: therapeutic medical physics, diagnostic medical physics, nuclear medical physics, MRI physics, and medical health physics. Therapeutic medical physics is also commonly called radiation oncology physics. These areas are not organized into identical certification categories by every professional body.
A simplified overview. Clinical training and certification requirements depend on the specialty and the certifying body. Some specialties have separate board certifications, while others are included within broader certification categories; the table below sets out how the ABR and CCPM group them.
Radiation oncology physics supports external beam radiation therapy treatment and brachytherapy. The work includes commissioning linear accelerators, validating external beam radiation treatment planning systems, establishing quality assurance procedures, and checking the physical accuracy of treatment delivery. Its experience with external beam radiation treatment planning, independent checks, and incident learning is valuable as radiopharmaceutical therapy grows.
Diagnostic imaging physics supports the quality and safety of imaging with CT, radiography, fluoroscopy, mammography and ultrasound. Image quality, protocol optimization, patient radiation dose where applicable, display performance and artefacts all require specialist knowledge, alongside equipment acceptance and ongoing testing. Some certification frameworks also include MRI within this specialty, although it has a distinct set of physical principles and safety considerations.
Nuclear medicine physics supports imaging and treatment using radiopharmaceuticals. Its scope includes PET/CT and SPECT/CT quantification, radionuclide calibrators, physics aspects of cyclotron and radiopharmacy production and quality control, internal dosimetry, and radiation safety.
In our own group we use the name Molecular Imaging and Therapy physics, because, in my opinion, it better describes the work we do today. We quantify molecular imaging studies, support radiopharmaceutical therapy, estimate patient-specific absorbed doses, develop clinical informatics tools, and help bring new theranostic technologies into clinical practice. The name makes both the imaging and therapy responsibilities explicit.
Therapy has been part of nuclear medicine WebsiteImportant Moments in the History of Nuclear MedicineVisit the website . What has expanded is the range of treatments and the opportunity to use quantitative imaging and dosimetry to guide them. In theranostics, imaging and therapy are closely connected: imaging can help identify an appropriate molecular target, while measurements after treatment can show where the radiopharmaceutical went and support absorbed dose estimation. The physics expertise needs to support that whole process.
I see Molecular Imaging and Therapy physics as the continuing development of the nuclear medicine physics specialty, with its training and certification foundation supporting an expanding clinical role. That is why I think the name matters as it helps make the expertise and responsibility behind a modern theranostics program more visible.
Magnetic resonance imaging physics supports imaging with magnetic fields, radiofrequency pulses and gradients. The work includes image quality assessment, protocol optimization, artefact investigation and MRI safety. MRI does not use ionizing radiation, but its physical and safety challenges still require specialist expertise. The CCPM offers a separate MRI certification, while MRI is included in the ABR's Diagnostic Medical Physics examination content.
Medical health physics focuses on radiation protection in healthcare. Its work includes shielding, occupational exposure monitoring, radiation surveys, radioactive material handling, contamination control, waste management and support for radiation safety programs. This expertise is particularly relevant when expanding radiopharmaceutical therapy services. Radiation protection is also part of the other specialties, so these responsibilities overlap and need to be agreed within each institution. The Journal articleAAPM–HPS medical physics practice guideline 16.a: medical health physics scope of practiceRead the paper describes this subfield in more detail.
These five areas are all part of medical physics, but each does not necessarily have its own board certification. The AAPM defines the subfields and qualification criteria, while certification boards group them differently. Here is how the ABR and CCPM organize their certifications:
| Area of practice | ABR certification category | CCPM certification category |
|---|---|---|
| Radiation oncology physics | Therapeutic Medical Physics | Radiation Oncology Physics |
| Diagnostic imaging physics | Diagnostic Medical Physics | Diagnostic Radiological Physics |
| Nuclear medicine physics | Nuclear Medical Physics | Nuclear Medicine Physics |
| MRI physics | Included within Diagnostic Medical Physics | Magnetic Resonance Imaging |
| Medical health physics | No separate certificate under this name | No separate certificate under this name |
The table compares certificate categories, not the full scope of an individual's competence. Sources: ABR certification categories, ABR diagnostic examination content, and CCPM certification categories.
For medical health physics, the AAPM qualification framework recognizes several certification routes, including specified ABR, ABMP, ABSNM and ABHP credentials, with additional experience requirements where stated. The absence of a separately named certificate from the ABR or CCPM does not mean that the work is outside medical physics.
There is overlap across these areas, particularly in hybrid imaging, therapy, and radiation protection. The important point is that a shared foundation does not make our clinical expertise interchangeable. With that broader picture in mind, the rest of this article focuses on how specialist expertise can support a growing theranostics program.
How the profession organizes that
Specialty training and certification are built into the way the profession defines qualification for independent clinical practice. The terminology varies across countries, but the importance of competence in the specialty being practised is consistent.
WebsiteResidency Education ProgramsVisit the website accredits clinical residencies in radiation oncology physics, in medical imaging, and in nuclear medicine physics. The standards set out specialty-specific clinical competencies.
WebsiteDefinition of a Qualified Medical PhysicistVisit the website defines a Qualified Medical Physicist as someone competent to independently provide clinical services "in one or more of the subfields of medical physics". Its definition explicitly connects qualification to specialty certification:
A qualified medical physicist is qualified to practice only in the subfield(s) in which they are certified.
AAPM lists five subfields: therapeutic, diagnostic and nuclear medical physics, plus medical health physics and MRI physics. Each has its own scope of practice, set out in Professional Policy 17.
WebsiteGet Certified in Medical PhysicsVisit the website certifies three specialties: Diagnostic Medical Physics, Therapeutic Medical Physics, and Nuclear Medical Physics. Part 1 of the process is shared, while Parts 2 and 3 are specialty-specific. The ABR also provides a pathway for additional specialty certification. A physicist already certified in one specialty who wants to add another completes at least a year of additional structured clinical training, supervised by someone certified in that field, under a prospective training plan approved by the ABR, with an attestation at the end.
That additional training recognizes that expertise in one specialty does not automatically establish competence in another.
WebsiteAbout CertificationVisit the website , in Canada, offers certification in four distinct sub-specialties: Diagnostic Radiological Physics, Magnetic Resonance Imaging, Nuclear Medicine Physics, and Radiation Oncology Physics. Candidates declare their sub-specialty when they apply, and separate written and oral exams are administered for each.
Journal articleEFOMP policy statement 16: The role and competences of medical physicists and medical physics experts under 2013/59/EURATOMRead the paper builds the European competence framework for the Medical Physics Expert around radiation oncology, diagnostic and interventional radiology, and nuclear medicine, each with its own mission statement and competence profile. EFOMP and the EANM went further and published a joint curriculum for Journal articleCurriculum for education and training of Medical Physicists in Nuclear MedicineRead the paper .
Journal articleRoles and Responsibilities, and Education and Training Requirements for Clinically Qualified Medical PhysicistsRead the paper defines the roles and responsibilities of the clinically qualified medical physicist by sub-specialty, and publishes a separate clinical training guide for each: Journal articleClinical Training of Medical Physicists Specializing in Nuclear MedicineRead the paper , Journal articleClinical Training of Medical Physicists Specializing in Radiation OncologyRead the paper , and Journal articleClinical Training of Medical Physicists Specializing in Diagnostic RadiologyRead the paper . Each guide addresses the competencies needed for that specialty.
WebsiteMedical PhysicsVisit the website classifies medical physics into sub-fields, including radiation oncology physics, medical imaging physics, nuclear medicine physics and medical health physics, and defines the clinical medical physicist as a health professional competent to practise independently in one or more of the subfields.
The point is that qualification is specific to the work being done. In the AAPM definition, specialty board certification is a requirement for qualification to practise independently in that subfield. Certification in one specialty does not establish qualification in another. Appropriate clinical training and ongoing competence are also essential, while international recognition pathways and local requirements vary.
The question theranostics is asking all of us
With that overview in mind, I want to focus on nuclear medicine (molecular imaging and therapy) physics and radiation oncology physics. The expansion of radiopharmaceutical therapy is bringing these two specialties into closer collaboration, particularly around absorbed dose estimation and treatment decisions. Understanding how their training and measurement methods differ helps explain what each contributes and where additional training is needed.
As radiopharmaceutical therapy expands, more centres are building services and asking how to support them. Alongside treatment delivery, there is an opportunity to measure where the radiopharmaceutical went, how long it remained there, and what absorbed doses tumours and healthy organs received.
This raises a practical question: who takes responsibility for each part of the radiopharmaceutical therapy workflow, from activity measurement and treatment administration to imaging, image reconstruction, dosimetry and radiation safety?
These responsibilities are shared across the clinical team. Each part needs a clearly identified lead with the appropriate training and qualifications, together with agreed checks at the steps connecting them. For medical physics, that means defining responsibility for the equipment, measurements and quantitative methods that support treatment administration, imaging, and absorbed dose estimation.
Radiation oncology physicists have specialist training in external beam radiation treatment planning, beam calibration and modelling, treatment delivery verification, and clinical quality assurance. Their work establishes how a prescribed radiation treatment will be delivered accurately, using commissioned treatment systems and validated dose calculation methods, including Monte Carlo where appropriate.
Nuclear medicine physicists have specialist training in PET and SPECT imaging system performance, detector response, calibration, acquisition protocols and image reconstruction. This includes understanding how attenuation and scatter corrections, spatial resolution, count-rate losses and reconstruction settings affect quantitative accuracy. Their expertise also covers radionuclide activity measurements, radiopharmaceutical biokinetics, and absorbed dose calculation from activity distributed within the patient over time. In radiopharmaceutical therapy, the absorbed dose estimate depends on this entire measurement and reconstruction process. Validating it is a core responsibility of nuclear medicine physics and requires training and clinical competence in that specialty.
Radiation safety also requires different practical expertise in these settings. For linac-based external beam treatment, protection centres on shielding, access controls, interlocks and safe operation during beam delivery. Sealed radioactive sources require controls for handling, storage, security and source recovery. In nuclear medicine, unsealed radioactive material introduces additional considerations like contamination, potential internal exposure, radioactive waste, and patients who continue to emit radiation and excrete radioactive material after administration. Protection therefore extends beyond the treatment room to patient care, release instructions and precautions for families and caregivers. Radiation safety is a shared responsibility, but the procedures and training need to reflect these different exposure pathways.
Both specialties use the principles of time, distance, and shielding, but the practical balance differs. In linac-based external beam treatment, the high dose rates during irradiation make structural shielding and controlled access central to protection. In nuclear medicine, shielding is one part of a wider approach. We can also organize workflows to reduce time spent close to a source, use distance effectively, and account for radioactive decay and biological clearance when planning care and patient instructions. The appropriate combination depends on the radionuclide, activity and clinical situation, alongside measures to prevent contamination. This requires a different practical perspective: understanding how to combine these controls to protect staff, patients and families while supporting the care the patient needs.
The IAEA's Journal articleRadiation Protection and Safety in Medical Uses of Ionizing RadiationRead the paper reflects these different approaches, with guidance on equipment safety, radiation protection, patient release and precautions for families and caregivers. The appropriate controls depend on the source, the treatment and the clinical situation.
These two specialties share tools and physical principles, but qualification for independent practice is specific to the specialty. Experience in external beam radiation treatment planning does not, by itself, establish competence in quantitative nuclear medicine imaging or radiopharmaceutical dosimetry. Equally, a nuclear medicine physicist's expertise does not, by itself, qualify them to take independent responsibility for external beam radiation treatment planning, even when PET images are used to guide the plan. In either direction, moving into another specialty requires the appropriate clinical training, supervision and certification. Collaboration needs to be supported by clearly assigned clinical responsibilities and respect for each specialty's expertise.
The importance of training and expertise in nuclear medicine for radiopharmaceutical therapy is also emphasized in SNMMI's 2025 Journal articleRadiopharmaceutical Therapy: Rapid Growth, Rising Challenges, and the Critical Need for ExpertiseRead the paper , Radiopharmaceutical Therapy: Rapid Growth, Rising Challenges, and the Critical Need for Expertise. It describes radiopharmaceutical dosimetry as a specialization within nuclear medicine and emphasizes knowledge of radiobiology, radionuclide decay, radiopharmaceutical pharmacokinetics and pharmacodynamics, and dosimetry for unsealed sources, alongside specialty certification.
For me, the practical implication is that we need collaboration and clearly assigned responsibility throughout the radiopharmaceutical therapy workflow. This includes the physics supporting activity measurement, treatment administration, imaging, image reconstruction, dosimetry and radiation safety. Each part needs oversight from someone with the appropriate training and qualifications. Calculating absorbed dose is one part of that wider responsibility, and its reliability depends on the measurements and decisions made throughout the process.
Two measurement chains, one unit
External beam radiotherapy and radiopharmaceutical therapy both report absorbed dose in gray, but the measurements behind that estimate differ.
In external beam radiotherapy, we control the beam delivery. A linear accelerator generates radiation electrically, while brachytherapy usually uses sealed radioactive sources positioned in or near the treatment region. In radiopharmaceutical therapy, we administer a radiopharmaceutical whose distribution and clearance determine where radiation is delivered over time. Understanding that distribution is central to estimating absorbed dose.
The diagram illustrates common workflows. External beam treatment accounts for setup and anatomical changes. Radiopharmaceutical therapy can use pretherapeutic dosimetry and information from previous cycles to guide subsequent treatment.
In external beam radiotherapy, beam output is calibrated with traceability to reference standards. A planning CT provides anatomical and density information. Immobilization and image guidance help reproduce the intended setup, while motion and anatomical changes need to be managed. The treatment plan is calculated and reviewed before delivery, with quality assurance and verification supporting its delivery.
In radiopharmaceutical therapy, absorbed dose estimation depends on measuring or estimating the activity distribution over time. Post-treatment measurements can characterize the dose from a cycle and help guide a later one. Pretherapeutic measurements can also support planning, with assumptions about how well they predict treatment kinetics. Each part of this process requires validation:
- Activity measurement. A radionuclide calibrator needs a validated setting for the radionuclide and measurement geometry. Residual activity in the syringe and administration line affects the estimate of administered activity. Errors can affect administration records, calibration or subsequent calculations, depending on how those measurements are used.
- Quantitative emission imaging. A SPECT or PET system needs calibration so that reconstructed values can be related to activity. Attenuation, scatter, resolution, partial volume effects, count-rate losses and reconstruction settings all matter. An image can be suitable for visual interpretation while still being unsuitable for quantitative dosimetry.
- Time. Activity changes as the radiopharmaceutical distributes, clears and decays. Measurements at multiple time points help characterize those changes. Simplified or single-time-point methods can be useful when validated for the therapy, tissue and clinical question, but they introduce assumptions that need to be understood. Registration, curve fitting and integration also contribute uncertainty.
- Dose calculation. Organ-level S-values, voxel kernels, and Monte Carlo methods relate activity over time to energy deposited in tissue. Segmentation, tissue mass, registration and the calculation model all influence the estimate.
- Radiobiology. Protracted irradiation, changing dose rates and heterogeneous activity distributions affect how absorbed dose relates to biological response. Alpha emitters add questions about high linear energy transfer, relative biological effectiveness and activity distribution at small scales. Comparisons with external beam treatment require care.
The Journal articleEANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculationsRead the paper describes how uncertainties in these measurements and models contribute to the final absorbed dose estimate. Their size depends on the workflow, tissue and method. A single percentage cannot describe every application.
As I discussed in Dosimetry Is a Staircase, Not an On/Off Switch, the level of measurement should match the clinical decision. A simpler method can be appropriate, provided its assumptions and limitations have been evaluated.
Where oversimplification becomes a problem
Dosimetry software has made this work more accessible. It can help with segmentation, registration, curve fitting, dose calculation and reporting. The team still needs to validate the measurements and assumptions supplied to it.
For example, an incorrect camera calibration can scale the activity values in an otherwise plausible-looking image. Those values then enter the time–activity curve and absorbed dose calculation. The report may look entirely reasonable unless there is an independent check capable of detecting the error.
As a simplified example, suppose the image-derived activity values are scaled 25% too high. With the same segmentation, time–activity model and dose calculation method, the time-integrated activity and absorbed dose estimate will also be 25% too high. The image can retain the same relative contrast when displayed with automatic scaling. This is an illustrative example, not a clinical tolerance.
Illustrative example only. These are not patient data, an expected error rate, or a clinical tolerance value. Both images are displayed with automatic normalization, so they look the same and only the calibrated scale differs. The example isolates a uniform scaling error in the image activity calibration, with every other input unchanged; other errors do not necessarily scale a dose estimate in this way.
A similar concern applies to count-rate losses at an early imaging time point, partial volume effects in a small lesion, or a time–activity model that does not represent the measured kinetics. These problems need different checks. A successful software calculation does not establish that the input data were suitable.
This is why nuclear medicine physics training matters. Understanding how the camera measures activity, how the radionuclide calibrator is used, and how acquisition and reconstruction affect quantification is part of the specialty's clinical expertise. That knowledge needs to be present when protocols are developed and when unexpected results are reviewed.
Supporting colleagues entering the field
Physicists from other specialties can make substantial contributions to radiopharmaceutical therapy. Many already do. External beam radiation treatment planning, independent checks, uncertainty analysis and incident learning are important strengths to bring into a growing service.
A colleague moving into nuclear medicine physics should have access to structured, supervised clinical training, mentored by someone certified in that specialty. The ABR's additional-specialty certification pathway is one concrete example of how that transition can be supported and assessed. Local credentialing and scope-of-practice requirements also need to be met.
Vendor training can help a team use a particular system, but it cannot replace the clinical training and board certification required for independent practice in a specialty. Supervised clinical training develops the broader judgment needed to decide whether a method is appropriate, recognize unreliable measurements and investigate discrepancies. Specialty board certification provides a formal assessment of that knowledge and competence.
This is also part of the motivation behind the dosimetry curriculum I have been developing with SNMMI for technologists, physicians and physicists. We are releasing modules as the course develops, with the aim of making dosimetry education more accessible and helping colleagues understand the measurements, methods and assumptions involved. You can find course material on SNMMI's learning platform. Education across professions can strengthen collaboration and support further training. It complements the supervised clinical experience and specialty board certification needed for independent physics practice.
Making these pathways accessible is part of expanding theranostics responsibly. Shared training, mentorship and collaboration between centres can help services build capability while working toward specialty qualification.
What great looks like
Here is how I think we can bring the specialties together in a theranostics program. These are complementary contributions with areas of overlap, and responsibilities should be agreed explicitly within the local team.
Molecular imaging and therapy physics provides specialist oversight of the quantitative workflow. This includes radionuclide measurements, camera calibration, validated acquisition and reconstruction protocols, activity quantification, biokinetics and time-integrated activity. It also includes the physics aspects of radiopharmacy quality control, patient release and contamination control, working with the professionals responsible for those services.
Radiation oncology physics brings rigorous quality control and a well-established approach to treatment verification. Our radiation oncology physics colleagues have substantial experience in commissioning treatment systems, setting tolerances and action levels, performing independent checks, documenting review and approval, and learning from incidents. I think this is one of the most valuable contributions they bring to theranostics. We should learn from that rigour and apply it consistently in nuclear medicine, adapting the checks to our equipment, measurements and radiopharmaceutical therapy workflows.
That means defining what needs to be checked, how often, by whom, and what happens when a result falls outside an agreed tolerance. Working together can help us build those processes into routine practice as services expand. Radiation oncology physicists also contribute expertise in external beam radiation treatment planning, dose calculation and the assessment of previous external beam treatment alongside radiopharmaceutical therapy, with attention to the limits of combining dose estimates across modalities.
Physicists also work alongside nuclear medicine physicians, radiation oncologists, technologists, radiopharmacists, nurses, and other colleagues. The physics responsibilities need to fit into that wider clinical team.
The joint WebsiteACR–AAPM–ACNM–SNMMI–SPR Technical Standard for Therapeutic Procedures Using RadiopharmaceuticalsVisit the website describes training for qualified medical physicists in these programs, including RPT training consistent with WebsiteEssentials and Guidelines for Clinical Medical Physics Residency Training ProgramsVisit the website and procedure-specific training at their institution.
There is also work underway to strengthen training across specialties. In September 2026 the AAPM approved WebsiteTask Group No. 482: Radiopharmaceutical Therapy CurriculumVisit the website . Its charge includes developing curriculum recommendations and competencies in dosimetry, radiation safety, radiobiology, instrumentation and clinical workflow for integration into radiation oncology, diagnostic imaging and nuclear medicine training pathways. These are recommendations being developed, rather than a completed training standard.
My recommendation is that the named molecular imaging and therapy physicist, with board certification in nuclear medicine physics and responsibility for the quantitative imaging and dosimetry workflow, should:
- commission and validate the quantitative workflow, including the interfaces between measurement systems and dosimetry software;
- approve acquisition, reconstruction and analysis protocols within the physics scope of practice;
- establish checks and assess whether uncertainties are appropriate for the clinical decisions being supported;
- supervise relevant physics training and review competence before independent work; and
- investigate discrepancies and revalidate the workflow when equipment, software or methods change.
This responsibility requires involvement in the service and the authority to address problems. Other team members can perform and develop parts of the workflow according to their training, competence and agreed responsibilities.
For a centre without an on-site specialist, a formal partnership with an experienced centre may help provide oversight, review and mentorship, where local requirements allow. The arrangement needs sufficient time, access to the relevant systems and data, and a clear understanding of who is responsible for what. Building access to expertise should be part of the service plan.
Bringing the expertise together
Medical Physics Day is a chance to recognize the different specialties within our profession. Theranostics gives us an opportunity to bring that expertise together to improve patient care.
I would like to see programs grow with molecular imaging and therapy physics expertise built in from the beginning, supported by colleagues in radiation oncology and diagnostic imaging physics. We should also make it easier for physicists to gain the training and certification needed to contribute independently in a new specialty.
For patients, this means a team that understands the measurements, checks the calculations, and can explain the uncertainty behind a treatment decision. That is the service we should be building together.
This article reflects my own views and is written for education and discussion. It is not a statement of policy for any institution, nor a substitute for local scope-of-practice regulations or professional body guidance.
Comments
Join the discussion! Comments are powered by GitHub Discussions - sign in with your GitHub account to participate.